Conectandolo directamente en el ptr los valores no varian apenas asi que...
y si es directa o indirecta no lo se la central es bastante antigua y no creo yo que hayan renovado nada, lo que si te puedo decir es que paso por un subreparto que esta bastante cerquita.
RE-EDITO:
Statistics -- ADSL
Mode: G.DMT
Type: Interleave
Line Coding: Trellis On
Status: No Defect
Link Power State: L0
Downstream Upstream
SNR Margin (dB): 8.9 23.0
Attenuation (dB): 54.0 31.5
Output Power (dBm): 19.1 12.3
Attainable Rate (Kbps): 4640 1056
Rate (Kbps): 4096 512
K (number of bytes in DMT frame): 129 17
R (number of check bytes in RS code word): 16 8
S (RS code word size in DMT frame): 1 8
D (interleaver depth): 64 2
Delay (msec): 16 4
Super Frames: 5780 5778
Super Frame Errors: 0 0
RS Words: 393106 49113
RS Correctable Errors: 188 0
RS Uncorrectable Errors: 0 N/A
HEC Errors: 0 0
OCD Errors: 0 0
LCD Errors: 0 0
Total Cells: 949715 0
Data Cells: 363680 0
Bit Errors: 0 0
Total ES: 0 0
Total SES: 0 0
Total UAS: 15 0
!increible!,lo he solucionado, como podeis ver los valores han mejorado bastante con respecto a ayer, ya que estoy seguro de haber encontrado la fuente de todo mal
![sonrisa [sonrisa]](/images/smilies/nuevos/risa_ani1.gif)
, por lo visto todo el problema de ruido y atenuacion venia por la induccion que creaba la instalacion electrica de mi casa, asi que saco cable y lo pongo por otra parte y fuera todo arreglado, al menos a primera vista seguire haciendo pruebas a ver que tal.